Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 26, 2021, 06:08 PM
  • 15 0253_15 0252_05262021_111922.mp4

Date
05/26/2021
W/O
890822
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00627
PipeID
P12175
Time
11:08 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8969
Sewer Name
15 SAN JOSE CREEK TRUNK
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
34
Purpose
Routine Assessment
Project
WO_890822_TV15001_MAY2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
15 0253
Downstream MH
15 0252
Dir. of Survey
Downstream
Length Surveyed
276.9 ft.
Total Length
276.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
4124
O&M Rating
12
Overall Index
3
Overall Quick
Overall Rating
15
Pipe schematic from manhole 15 0253 to 15 0252
MH: 15 0253MH: 15 0252downstream0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 02530 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start7 ft. MGO - General Observation - MAG COAT7 ft. OBZ - Obstacles Other, 10 %of cross sectional area, at 06 o'clock, Start - UNDER FLOW52.4 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 8"150.8 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 8"255.3 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 8"276.9 ft. AMH - Downstream Manhole, Survey Ends - 15 0252276.9 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish276.9 ft. OBZ - Obstacles Other, 10 %of cross sectional area, at 06 o'clock, Finish - UNDERF LOW

Observation photos (6)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT

    7 ft. - General Observation - MAG COAT

  • Obstacles Other, 10 %of cross sectional area, at 06 o'clock, Start - UNDER FLOW

    7 ft. - Obstacles Other, 10 %of cross sectional area, at 06 o'clock, Start - UNDER FLOW

  • Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 8"

    52.4 ft. - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 8"

    150.8 ft. - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 8"

    255.3 ft. - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 8"

Observations (12)

DistanceCodeObservation
276.9AMH15 0252
150.8TBC
7MGOMAG COAT
276.9SAV
0MWL
0AMH15 0253
0MWM
7OBZUNDER FLOW
276.9OBZUNDERF LOW
52.4TBC
2SAV
255.3TBC

Properties (6)

custom_field_three
AGGEGATE VISBLE
custom_field_two
3
customer
1
datetime
2021-05-26T11:08:46-07:00
documentation
PRO PIPE
is_lateral_inspection
false