Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 24, 2021, 11:49 AM
  • 18 0748_18 0747A_05242021_045529.mp4

Date
05/24/2021
W/O
891160
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00706
PipeID
P26783
Time
4:49 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8876
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
WHITTIER
Loc. details
Light Highway
Location Code
C
District
District 18
Page No.
26
Purpose
Routine Assessment
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Other
Height
30 in.
Upstream MH
18 0748
Downstream MH
18 0747A
Dir. of Survey
Downstream
Length Surveyed
120.1 ft.
Total Length
120.1 ft.
Structural Index
3
Structural Quick
3D2D
Structural Rating
115
O&M Index
2
O&M Quick
2D00
O&M Rating
46
Overall Index
2
Overall Quick
Overall Rating
161
Pipe schematic from manhole 18 0748 to 18 0747A
MH: 18 0748MH: 18 0747Adownstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 07480 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/UNKNOWN2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start4.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.8 ft. MGO - General Observation - 65% MAG COAT118 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish120.1 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE120.1 ft. AMH - Downstream Manhole, Survey Ends - 18 0747A120.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish120.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
4.8SAP
120.1MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWL
120.1AMH18 0747A
0MWM
4.8SSS
0AMH18 0748
4.8MGO65% MAG COAT
0MGOCONN @ MH 9 O'CLOCK/UNKNOWN
2DAGS
120.1SSS
118DAGS
120.1SAP

Properties (7)

additional_info
630138052421002
custom_field_three
AGGREGATE PROJECTING/SPALLING
custom_field_two
2
customer
1
datetime
2021-05-24T04:49:59-07:00
documentation
PROPIPE
is_lateral_inspection
false