Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 25, 2021, 08:54 AM
  • 18 0742_18 0741_05252021_020555.mp4

Date
05/25/2021
W/O
891160
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00706
PipeID
P14595
Time
1:54 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8878
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
26
Purpose
Routine Assessment
Project
RFIR_WO_891160_TV18103_MAY2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
18 0742
Downstream MH
18 0741
Dir. of Survey
Downstream
Length Surveyed
217.1 ft.
Total Length
217.2 ft.
Structural Index
3
Structural Quick
513H
Structural Rating
220
O&M Index
2
O&M Quick
2H00
O&M Rating
86
Overall Index
2
Overall Quick
Overall Rating
306
Pipe schematic from manhole 18 0742 to 18 0741
MH: 18 0742MH: 18 0741downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 07420 ft. MGO - General Observation - ROACHES @ MH0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - 65% MAG COAT2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start192.6 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES215 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish215 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish217 ft. MGO - General Observation - ROACHES @ MH217.2 ft. AMH - Downstream Manhole, Survey Ends - 18 0741217.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES

    192.6 ft. - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
2DAGS
217MGOROACHES @ MH
217.2AMH18 0741
2.1MGO65% MAG COAT
0AMH18 0742
0MGOROACHES @ MH
217.2SAV
2.1SAV
215DAGS
2SSS
215SSS
0MWM
0MWL
192.6SRV

Properties (7)

additional_info
630138052421202
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-05-25T01:54:57-07:00
documentation
PROPIPE
is_lateral_inspection
false