Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 20, 2021, 09:45 AM
  • 18 0431_18 0430_05202021_033022.mp4

Date
05/20/2021
W/O
891049
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00675
PipeID
P14279
Time
2:45 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8873
Sewer Name
18 FLORENCE AVENUE TRUNK
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_891049_TV18097_MAY2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
18 0430
Downstream MH
18 0431
Dir. of Survey
Upstream
Length Surveyed
401.5 ft.
Total Length
401.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 18 0430 to 18 0431
MH: 18 0430MH: 18 0431upstream0 ft. MSA - Survey Abandoned - CAM BLKD BY DEBRIS/ SLUDGE 10%0 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish25.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"397.3 ft. MGO - General Observation - MAG COAT397.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start401.5 ft. MWM - Water Mark, 15 %of cross sectional area401.5 ft. AMH - Downstream Manhole, Survey Begins - 18 0430401.5 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
4.2MGOMAG COAT
375.6TF
0MWM
401.5MSACAM BLKD BY DEBRIS/ SLUDGE 10%
4.2SAV
401.5SAV
0AMH18 0430
0MWL

Properties (6)

additional_info
630138051921203
custom_field_two
5
customer
1
datetime
2021-05-20T02:45:57-07:00
documentation
PROPIPE
is_lateral_inspection
false