- Date
- 06/10/2021
- W/O
- 890820
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00349
- PipeID
- P02981
- Time
- 12:41 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8895
- Sewer Name
- 02 DISTRICT #2 INTERCEPTOR TRUNK
- City
- COMMERCE
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 20
- Purpose
- Routine Assessment
- Project
- WO_890820_TV02317_MAY2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 63 in.
- Width
- 36 in.
- Upstream MH
- 02 1410
- Downstream MH
- 02 1409
- Dir. of Survey
- Downstream
- Length Surveyed
- 573.5 ft.
- Total Length
- 573.5 ft.
- Structural Index
- 3
- Structural Quick
- 3V2V
- Structural Rating
- 567
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 567
Pipe schematic from manhole 02 1410 to 02 1409 Observation photos (3)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

7.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

28.5 ft. - General Observation - MAG COATING THROUGHOUT