Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 20, 2021, 09:12 AM
  • 01 0959_01 0958_05202021_022232.mp4

Date
05/20/2021
W/O
890942
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00228
PipeID
P01796
Time
2:12 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8964
Sewer Name
01 WRIGHT ROAD TRUNK
City
BELL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_890942_TV01251_MAY2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
33 in.
Upstream MH
01 0959
Downstream MH
01 0958
Dir. of Survey
Downstream
Length Surveyed
300 ft.
Total Length
300 ft.
Structural Index
2
Structural Quick
2D00
Structural Rating
46
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
50
Pipe schematic from manhole 01 0959 to 01 0958
MH: 01 0959MH: 01 0958downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 09590 ft. MWM - Water Mark, 50 %of cross sectional area139 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start185.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish220.4 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES224.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start289 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish300 ft. AMH - Downstream Manhole, Survey Ends - 01 0958

Observation photos (3)

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    139 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    220.4 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    224.9 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
139CL
0MWL
0AMH01 0959
185.7CL
289CL
220.4CL
224.9CL
300AMH01 0958
0MWM

Properties (7)

custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2021-05-20T02:12:24-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
10286