Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 21, 2021, 05:35 AM
  • 01 0955_01 0954_05202021_224800.mp4

Date
05/20/2021
W/O
890942
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00228
PipeID
P01792
Time
10:35 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8965
Sewer Name
01 WRIGHT ROAD TRUNK
City
BELL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_890942_TV01251_MAY2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
36 in.
Upstream MH
01 0955
Downstream MH
01 0954
Dir. of Survey
Downstream
Length Surveyed
274.9 ft.
Total Length
274.9 ft.
Structural Index
2
Structural Quick
2F00
Structural Rating
70
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
74
Pipe schematic from manhole 01 0955 to 01 0954
MH: 01 0955MH: 01 0954downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 09550 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK49.3 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES62.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES65 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start109.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish130.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES161.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start274.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish274.9 ft. AMH - Downstream Manhole, Survey Ends - 01 0954

Observation photos (5)

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    49.3 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    62.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    65 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    130.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    161.7 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
130.1CL
0MWM
0MWL
274.9CL
0AMH01 0955
49.3CL
65CL
62.2CL
0MGOCONNECTION AT THE MH 3 OC'LOCK
161.7CL
274.9AMH01 0954
109.7CL

Properties (7)

custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2021-05-20T22:35:31-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
10286