Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 10, 2021, 12:12 PM
  • 08 0492_08 0048_6102021_051604.mp4

Date
06/10/2021
W/O
0890878
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00021
PipeID
P00550
Time
5:12 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1841
Sewer Name
08 VICTORIA STREET TRUNK
City
COMPTON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Capital Improvement Program Assesment
Project
20210610MDM_VICTORIA_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
08 0492
Downstream MH
08 0048
Dir. of Survey
Downstream
Length Surveyed
300.8 ft.
Total Length
300.8 ft.
Structural Index
2
Structural Quick
4137
Structural Rating
63
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
63
Pipe schematic from manhole 08 0492 to 08 0048
MH: 08 0492MH: 08 0048downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 5:15AM2.3 ft. FC - Fracture Circumferential, from 09 to 01 o'clock, within 8 inches of joint: YES - HAIRLINE7.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, - SLIGHT27.4 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SL42.6 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL47.6 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H49.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped51.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped53.8 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H58.9 ft. FC - Fracture Circumferential, from 11 to 02 o'clock, within 8 inches of joint: YES - H63.6 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H100.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped102.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped109.9 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SL125.4 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H140.2 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - H140.2 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL151.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped153.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H154.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped176.3 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H181.3 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H181.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - S191.6 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H196.6 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SL201.3 ft. FC - Fracture Circumferential, from 01 to 02 o'clock, within 8 inches of joint: YES - SL201.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL202.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped224.4 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H234.5 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL239.5 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - H260.3 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H270.1 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H288.5 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - H294.8 ft. FC - Fracture Circumferential, from 09 to 04 o'clock, within 8 inches of joint: YES - SL300.2 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active300.8 ft. AMH - Downstream Manhole, Survey Ends - 5:40AM

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES,  - SLIGHT

    7.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, - SLIGHT

Observations (39)

DistanceCodeObservation
202.8TFCCapped
201.3FCSL
109.9FCSL
181.7FCS
239.5FCH
201.3FLSL
53.8FCH
300.2MGOConn. @ Mh, 3 O' Clock. Active
181.3FCH
7.4FMSLIGHT
42.6FCSL
270.1FLH
153.2FLH
151.4TFCCapped
288.5FLH
140.2FLH
0MWL
176.3FCH
0MWM
260.3FCH
47.6FLH
2.3FCHAIRLINE
125.4FCH
0AMH5:15AM
191.6FCH
100.2TFCCapped
102.9TFCCapped
27.4FCSL
234.5FCSL
51.8TFCCapped
196.6FCSL
224.4FCH
140.2FCSL
58.9FCH
49.1TFCCapped
154.5TFCCapped
294.8FCSL
63.6FLH
300.8AMH5:40AM

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2021-06-10T05:12:45-07:00
documentation
MARTIN,OLIVER 111,RAMIREZ
is_lateral_inspection
false