Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 10, 2021, 11:21 AM
  • 08 0493_08 0492_6102021_043455.mp4

Date
06/10/2021
W/O
0890878
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00021
PipeID
P00551
Time
4:21 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1841
Sewer Name
08 VICTORIA STREET TRUNK
City
COMPTON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Capital Improvement Program Assesment
Project
20210610MDM_VICTORIA_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
08 0493
Downstream MH
08 0492
Dir. of Survey
Downstream
Length Surveyed
295.6 ft.
Total Length
295.6 ft.
Structural Index
3
Structural Quick
423C
Structural Rating
106
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
106
Pipe schematic from manhole 08 0493 to 08 0492
MH: 08 0493MH: 08 0492downstream0 ft. AMH - Upstream Manhole, Survey Begins - 4:30AM0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Change - HAIRLINE AT JOINTS2 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Change - SLIGHT AT JOINTS2 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Change - HAIRLINE AY JOINTS2 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Change - SLIGHT AT JOINTS17.2 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT27.5 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - HAIRLINE43.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped46.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped46.2 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - SL63.6 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT83.4 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - H94.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped96.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL96.9 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H98.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped104.8 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H115 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SL119.6 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H119.7 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - H129.6 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - H134.8 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - H134.8 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H139.8 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - U139.8 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - U146.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped148.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped150.9 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H150.9 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H156.1 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H156.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H160.5 ft. FC - Fracture Circumferential, from 10 to 03 o'clock, within 8 inches of joint: YES - SL165.9 ft. FC - Fracture Circumferential, from 08 to 02 o'clock, within 8 inches of joint: YES - H175.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - H186.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H186.2 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H191.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - H192.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6", 6" - STUB194.3 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H195.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped202.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H202.7 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H207.3 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - H212.5 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL217.4 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SL243.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped246.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6" - STUB258.6 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - HAIRLINE263.3 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SL273.5 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - H273.5 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SL284.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped286.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H287.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped289.9 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H295.6 ft. AMH - Downstream Manhole, Survey Ends - 5:10AM

Observations (58)

DistanceCodeObservation
150.9FLH
43.9TFCCapped
156.1FLH
191.1FMH
0AMH4:30AM
202.7FCH
246.5TFCSTUB
192.2TFCSTUB
0MWM
17.2FCSLIGHT
115FCSL
63.6FCSLIGHT
119.6FCH
146.3TFCCapped
2FLHAIRLINE AT JOINTS
207.3FLH
94.6TFCCapped
273.5FCH
243.8TFCCapped
83.4FCH
104.8FCH
96.9FLSL
98.5TFCCapped
195.3TFCCapped
284.7TFCCapped
258.6FLHAIRLINE
150.9FLH
134.8FCH
2FLSLIGHT AT JOINTS
46.2TFCCapped
134.8FLH
287.9TFCCapped
165.9FCH
139.8FCU
139.8FLU
119.7FLH
263.3FCSL
217.4FCSL
129.6FCH
286.7FLH
156.1FLH
295.6AMH5:10AM
175.7FMH
96.9FCH
148.6TFCCapped
46.2FCSL
0MWL
160.5FCSL
27.5FCHAIRLINE
186.2FLH
202.7FLH
289.9FLH
212.5FCSL
273.5FCSL
186.2FLH
194.3FLH
2FCHAIRLINE AY JOINTS
2FCSLIGHT AT JOINTS

Properties (6)

custom_field_three
SLIGYT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2021-06-10T04:21:53-07:00
documentation
MARTIN,OLIVER 111,RAMIREZ
is_lateral_inspection
false