Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 10, 2021, 08:40 AM
  • 08 0507_08 0506_6102021_015645.mp4

Date
06/10/2021
W/O
0890917
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00021
PipeID
P00568
Time
1:40 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1840
Sewer Name
08 VICTORIA STREET TRUNK
City
COMPTON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Capital Improvement Program Assesment
Project
20210610MDM_VICTORIA_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
08 0506
Downstream MH
08 0507
Dir. of Survey
Upstream
Length Surveyed
324.9 ft.
Total Length
324.9 ft.
Structural Index
2
Structural Quick
4132
Structural Rating
38
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
38
Pipe schematic from manhole 08 0506 to 08 0507
MH: 08 0506MH: 08 0507upstream0 ft. AMH - Upstream Manhole, Survey Ends - 2:50AM53 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped55.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped58.6 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H58.6 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H73.5 ft. FC - Fracture Circumferential, from 11 to 03 o'clock, within 8 inches of joint: YES - SL76.4 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H107.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped109.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped121.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - SL121.7 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H122.9 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H127 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL128.5 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H129 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - HAIRLINE129 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT158.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped160.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped160.9 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL204.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped206.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped212.7 ft. FC - Fracture Circumferential, from 09 to 01 o'clock, within 8 inches of joint: YES - H224.4 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SL229.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - SL229.5 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - H243.8 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SL248.9 ft. B - Broken, from 12 to 02 o'clock, within 8 inches of joint: NO - OFFSET FRACTURE250.5 ft. MGP - General Photograph - SLIGHT FRACTURE 12:00256.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped257.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped271.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT307.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped310.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped324.9 ft. MWL - Water Level, 10 %of cross sectional area324.9 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active324.9 ft. MWM - Water Mark, 30 %of cross sectional area324.9 ft. AMH - Upstream Manhole, Survey Begins - 2:00AM

Observation photos (4)

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    53.5 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • General Photograph - SLIGHT FRACTURE 12:00

    74.4 ft. - General Photograph - SLIGHT FRACTURE 12:00

  • Broken, from 12 to 02 o'clock, within 8 inches of joint: NO - OFFSET FRACTURE

    76 ft. - Broken, from 12 to 02 o'clock, within 8 inches of joint: NO - OFFSET FRACTURE

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    195.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

Observations (37)

DistanceCodeObservation
197.9FCSL
118.7TFCCapped
14.5TFCCapped
271.9TFCCapped
215TFCCapped
0MWL
217.8TFCCapped
166.3TFCCapped
17TFCCapped
0MGOConn. @ Mh, 9 O' Clock. Active
112.2FCH
95.4FLSL
196.4FCH
251.4FCSL
74.4MGPSLIGHT FRACTURE 12:00
81.1FCSL
266.3FCH
0MWM
195.9FCHAIRLINE
324.9AMH2:50AM
100.5FCSL
248.5FCH
67.8TFCCapped
0AMH2:00AM
76BOFFSET FRACTURE
203.2FLSL
68.1TFCCapped
53.5FLSLIGHT
195.9FLSLIGHT
202FCH
164.4TFCCapped
164FCSL
203.2FCH
269.3TFCCapped
95.4FCH
120.5TFCCapped
266.3FCH

Properties (6)

custom_field_three
SLIGHT FRACTURE JOINT TO JOINT LONGER
custom_field_two
2
customer
LACSD
datetime
2021-06-10T01:40:33-07:00
documentation
MARTIN,OLIVER 111,RAMIREZ
is_lateral_inspection
false