- Date
- 06/09/2021
- W/O
- 0891156
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00075
- PipeID
- P08670
- Time
- 12:16 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1837
- Sewer Name
- B JOINT OUTFALL B - UNIT 1D
- City
- PICO RIVERA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 19
- Purpose
- Capital Improvement Program Assesment
- Project
- 20210608MDM_JOINT_OUTFALL_B_UNIT_1D
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 54 in.
- Upstream MH
- H 0327
- Downstream MH
- B 0184A
- Dir. of Survey
- Downstream
- Length Surveyed
- 69.8 ft.
- Total Length
- 69.8 ft.
- Structural Index
- 4
- Structural Quick
- 5241
- Structural Rating
- 16
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 20
Pipe schematic from manhole H 0327 to B 0184A Observation photos (4)

12.3 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

12.3 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

31.2 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

42.4 ft. - Surface Reinforcement Corroded, from 10 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR