Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 21, 2021, 06:50 AM
  • H 0554_H 0553_05202021_235925.mp4

Date
05/20/2021
W/O
890859
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00186
PipeID
P10978
Time
11:50 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8921
Sewer Name
H JOINT OUTFALL H - UNIT 8C
City
BALDWIN PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Routine Assessment
Project
WO_890859_TV15170_MAY2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
H 0554
Downstream MH
H 0553
Dir. of Survey
Downstream
Length Surveyed
149.1 ft.
Total Length
149.1 ft.
Structural Index
2
Structural Quick
2E00
Structural Rating
58
O&M Index
2
O&M Quick
2E11
O&M Rating
59
Overall Index
2
Overall Quick
Overall Rating
117
Pipe schematic from manhole H 0554 to H 0553
MH: H 0554MH: H 0553downstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 05542 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start10.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"10.7 ft. RFJ - Roots Fine Joint, at 10 o'clock, within 8 inches of joint: YESR67.2 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"75.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"115.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"123.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"146.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish149 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish149.1 ft. AMH - Downstream Manhole, Survey Ends - H 0553149.1 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK149.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (2)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • General Observation - COCKROACHES IN MANHOLE

    149.1 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (17)

DistanceCodeObservation
10.7TFA
123.9TF
0MGOCOCKROACHES IN MANHOLE
0MWL
75.4TF
149.1AMHH 0553
0MWM
146.7DAGS
149.1MGOCONNECTION AT MH 3 O'CLOCK
115.9TFC
67.2TFC
2DAGS
149SSS
149.1MGOCOCKROACHES IN MANHOLE
2.1SSS
0AMHH 0554
10.7RFJ

Properties (7)

additional_info
630069052021201
custom_field_three
LIGHT GREASE
custom_field_two
3
customer
1
datetime
2021-05-20T23:50:43-07:00
documentation
PRO PIPE
is_lateral_inspection
false