Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 17, 2021, 10:09 AM
  • 15 0186_15 0185_05172021_032349.mp4

Date
05/17/2021
W/O
891341
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00605
PipeID
P12110
Time
3:09 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8913
Sewer Name
15 FERRIS ROAD TRUNK
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
23
Purpose
Routine Assessment
Project
RFIR_WO_891341_TV15249_MAY2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0185
Downstream MH
15 0186
Dir. of Survey
Upstream
Length Surveyed
274.1 ft.
Total Length
274.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2J00
O&M Rating
108
Overall Index
2
Overall Quick
Overall Rating
111
Pipe schematic from manhole 15 0185 to 15 0186
MH: 15 0185MH: 15 0186upstream0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish0 ft. MSA - Survey Abandoned - DUE TO DAMAGED LINK PIPE. REVERSAL COMPLETE.1.2 ft. RPZD - Repair Other Defective, within 8 inches of joint: YES - DAMAGED LINK PIPE1.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"16 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES36 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"43.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"74.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"101.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"107 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"125.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"153 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"171.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"198.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"213.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"223.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"269.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"272.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start274.1 ft. MWL - Water Level, 10 %of cross sectional area274.1 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK274.1 ft. MWM - Water Mark, 35 %of cross sectional area274.1 ft. AMH - Downstream Manhole, Survey Begins - 15 0185274.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (5)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    258.1 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Repair Other Defective, within 8 inches of joint: YES - DAMAGED LINK PIPE

    272.9 ft. - Repair Other Defective, within 8 inches of joint: YES - DAMAGED LINK PIPE

  • Survey Abandoned - DUE TO DAMAGED LINK PIPE. REVERSAL COMPLETE.

    274.1 ft. - Survey Abandoned - DUE TO DAMAGED LINK PIPE. REVERSAL COMPLETE.

Observations (23)

DistanceCodeObservation
258.1CM
102.3TFA
0MWL
238.1TFC
0MGOCONNECTION AT MH 3 O'CLOCK
121.1TFA
172.9TFA
274.1DAGS
272.4TFA
167.1TFC
230.8TFC
274.1MSADUE TO DAMAGED LINK PIPE. REVERSAL COMPLETE.
75.2TFC
0MWM
0AMH15 0185
4.5TFA
50.2TFC
199.9TFA
272.9RPZDDAMAGED LINK PIPE
0MGOCOCKROACHES IN MANHOLE
2DAGS
148.5TFC
60.5TFC

Properties (7)

additional_info
630069051721003
custom_field_three
MULTIPLE CRACKS/DAMAGED LINK PIPE
custom_field_two
2
customer
1
datetime
2021-05-17T03:09:10-07:00
documentation
PRO PIPE
is_lateral_inspection
false