Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 20, 2021, 05:13 AM
  • 18 0833_18 0832_05192021_222945.mp4

Date
05/19/2021
W/O
891210
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00708
PipeID
P14696
Time
10:13 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8871
Sewer Name
18 SO WHITTIER OUTFALL TR, SECT 6
City
SANTA FE SPRINGS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_891210_TV18183_MAY2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
18 0832
Downstream MH
18 0833
Dir. of Survey
Upstream
Length Surveyed
288.4 ft.
Total Length
288.4 ft.
Structural Index
4
Structural Quick
4E31
Structural Rating
119
O&M Index
2
O&M Quick
3122
O&M Rating
7
Overall Index
4
Overall Quick
Overall Rating
126
Pipe schematic from manhole 18 0832 to 18 0833
MH: 18 0832MH: 18 0833upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 083353.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"63.2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish150.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"174.4 ft. RFB - Roots Fine Barrell, from 07 to 09 o'clock184.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start252.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"252.3 ft. RMC - Roots Medium Connection, at 02 o'clock, 25 %, within 8 inches of joint: NO260.9 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish285.3 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start285.3 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES288.4 ft. MWM - Water Mark, 15 %of cross sectional area288.4 ft. MWL - Water Level, 10 %of cross sectional area288.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES288.4 ft. AMH - Downstream Manhole, Survey Begins - 18 0832

Observation photos (5)

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    3.1 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Roots Medium Connection, at 02 o'clock, 25 %, within 8 inches of joint: NO

    36.1 ft. - Roots Medium Connection, at 02 o'clock, 25 %, within 8 inches of joint: NO

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    103.9 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Barrell, from 07 to 09 o'clock

    114 ft. - Roots Fine Barrell, from 07 to 09 o'clock

Observations (15)

DistanceCodeObservation
3.1FM
0MWM
288.4AMH18 0833
0MWL
27.5FM
225.2FM
0DAGS
114RFB
103.9FM
3.1FL
36.1TF
234.8TFC
137.5TFC
0AMH18 0832
36.1RMC

Properties (7)

additional_info
630138051921201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-05-19T22:13:24-07:00
documentation
PROPIPE
is_lateral_inspection
false