- Date
- 06/05/2021
- W/O
- 0890917
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00021
- PipeID
- P25927
- Time
- 4:20 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1832
- Sewer Name
- 08 VICTORIA STREET TRUNK
- City
- COMPTON
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 02
- Purpose
- Capital Improvement Program Assesment
- Project
- 20210602MDM_VICTORIA_STREET_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Upstream MH
- 08 0521
- Downstream MH
- 08 0520A
- Dir. of Survey
- Downstream
- Length Surveyed
- 266.9 ft.
- Total Length
- 266.9 ft.
- Structural Index
- 2
- Structural Quick
- 4132
- Structural Rating
- 34
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 34
Pipe schematic from manhole 08 0521 to 08 0520A Observation photos (5)

132.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

242 ft. - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SLIGHT

242.6 ft. - Repair Patch, from 08 to 11 o'clock, within 8 inches of joint: YES - PATCH REPAIR

242.6 ft. - Repair Patch, from 08 to 11 o'clock, within 8 inches of joint: YES - REPAIR PATCH

266.4 ft. - General Observation - SEVERE CORRISON CHANNEL WALL AT 3:00