Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 19, 2021, 05:38 AM
  • 18 0363_18 0362_05182021_224901.mp4

Date
05/18/2021
W/O
890902
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00714
PipeID
P14197
Time
10:38 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8869
Sewer Name
18 WASHINGTON BOULEVARD TRUNK
City
WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
09
Purpose
Routine Assessment
Project
WO_890902_TV18060_MAY2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0363
Downstream MH
18 0362
Dir. of Survey
Downstream
Length Surveyed
183.2 ft.
Total Length
183.2 ft.
Structural Index
2
Structural Quick
3F2F
Structural Rating
182
O&M Index
2
O&M Quick
412F
O&M Rating
76
Overall Index
2
Overall Quick
Overall Rating
258
Pipe schematic from manhole 18 0363 to 18 0362
MH: 18 0363MH: 18 0362downstream0 ft. MWM - Water Mark, 70 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 03630 ft. MWL - Water Level, 65 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start10.6 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"27.3 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES58.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN111.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"159.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"181 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish181 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish183 ft. MGO - General Observation - ROACHES @ MH183.2 ft. AMH - Downstream Manhole, Survey Ends - 18 0362183.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish183.2 ft. MGO - General Observation - CONN MH 9 O'CLOCK/CAPPED183.2 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/OPEN

Observation photos (2)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    27.3 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
183MGOROACHES @ MH
0MWM
183.2AMH18 0362
0AMH18 0363
27.3CL
10.6TFC
2CM
183.2CM
111.7TFC
183.2MGOCONN MH 9 O'CLOCK/CAPPED
0MWL
159.7TFC
58.8TFOPEN
181DAGS
183.2MGOCONN @ MH 3 O'CLOCK/OPEN
0MGOCONN @ MH 9 O'CLOCK/
2SSS
2DAGS
181SSS

Properties (7)

additional_info
630138051821201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-05-18T22:38:57-07:00
documentation
PROPIPE
is_lateral_inspection
false