Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 19, 2021, 05:49 AM
  • 18 0362_18 0361_05192021_000725.mp4

Date
05/18/2021
W/O
890902
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00714
PipeID
P14196
Time
10:49 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8869
Sewer Name
18 WASHINGTON BOULEVARD TRUNK
City
WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
09
Purpose
Routine Assessment
Project
WO_890902_TV18060_MAY2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0362
Downstream MH
18 0361
Dir. of Survey
Downstream
Length Surveyed
294.1 ft.
Total Length
294.2 ft.
Structural Index
3
Structural Quick
3K2K
Structural Rating
299
O&M Index
2
O&M Quick
422K
O&M Rating
124
Overall Index
2
Overall Quick
Overall Rating
423
Pipe schematic from manhole 18 0362 to 18 0361
MH: 18 0362MH: 18 0361downstream0 ft. MGO - General Observation - ROACHES @ MH0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/CAPPED0 ft. MWL - Water Level, 65 %of cross sectional area0 ft. MWM - Water Mark, 70 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 03620 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start27.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"75.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN110.8 ft. CM - Crack Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES124.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"129.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES158.4 ft. CM - Crack Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES171.4 ft. TSA - Tap Saddle Active, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6"180 ft. MWM - Water Mark, 50 %of cross sectional area220.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"292 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish292 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish292 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish294 ft. MGO - General Observation - ROACHES @ MH294.2 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/OPEN294.2 ft. AMH - Downstream Manhole, Survey Ends - 18 0361

Observation photos (4)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

    110.8 ft. - Crack Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    129.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

    158.4 ft. - Crack Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

Observations (24)

DistanceCodeObservation
294.2MGOCONN @ MH 3 O'CLOCK/OPEN
180MWM
2CM
0MGOROACHES @ MH
0MGOCONN @ MH 9 O'CLOCK/CAPPED
2DAGS
158.4CM
27.9TFC
124.9TFC
129.4CM
294MGOROACHES @ MH
0MWL
0MWM
292SSS
110.8CM
292CM
294.2AMH18 0361
220.1TFC
0AMH18 0362
2SSS
75.7TFOPEN
292DAGS
171.4TSA
0MGOCONN @ MH 3 O'CLOCK/

Properties (7)

additional_info
630138051821201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-05-18T22:49:41-07:00
documentation
PROPIPE
is_lateral_inspection
false