Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 18, 2021, 06:40 AM
  • 18 1239_18 1238_05172021_235111.mp4

Date
05/17/2021
W/O
890909
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01188
PipeID
P26198
Time
11:40 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8868
Sewer Name
18 EAST IMPERIAL HIGHWAY RELIEF TRUNK
City
SOUTH WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
26
Purpose
Routine Assessment
Project
WO_890909_TV18137_MAY2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 1239
Downstream MH
18 1238
Dir. of Survey
Downstream
Length Surveyed
282.6 ft.
Total Length
282.6 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 18 1239 to 18 1238
MH: 18 1239MH: 18 1238downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 12390 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area196.9 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES282.6 ft. AMH - Downstream Manhole, Survey Ends - 18 1238

Observation photos (1)

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    196.9 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

Observations (5)

DistanceCodeObservation
0AMH18 1239
282.6AMH18 1238
0MWM
0MWL
196.9CL

Properties (8)

additional_info
630138051721201
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2021-05-17T23:40:45-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
40099