Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 7, 2021, 06:15 AM
  • 18 0102_18 0101_05062021_232947.mp4

Date
05/06/2021
W/O
891153
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00698
PipeID
P13922
Time
11:15 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8847
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_891153_TV18177_MAY2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0102
Downstream MH
18 0101
Dir. of Survey
Downstream
Length Surveyed
225.6 ft.
Total Length
225.6 ft.
Structural Index
3
Structural Quick
3H2H
Structural Rating
226
O&M Index
2
O&M Quick
2H00
O&M Rating
88
Overall Index
2
Overall Quick
Overall Rating
314
Pipe schematic from manhole 18 0102 to 18 0101
MH: 18 0102MH: 18 0101downstream0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/OPEN0 ft. AMH - Upstream Manhole, Survey Begins - 18 01020 ft. MWL - Water Level, 25 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start56.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 8"59.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 8"97.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES108.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 8"110.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 8"159.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 8"162.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 8"208 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 8"211.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 8"223 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish223 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish225 ft. MGO - General Observation - ROACHES @ MH225.6 ft. AMH - Downstream Manhole, Survey Ends - 18 0101225.6 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE225.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish225.6 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/OPEN

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    97.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (24)

DistanceCodeObservation
162.5TFC
2SSS
225.6AMH18 0101
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
110.9TFC
208TFC
211.2TFC
159.5TFC
0MWM
225MGOROACHES @ MH
2.1SAV
225.6MGOCONN @ MH 9 O'CLOCK/ACTIVE
56.4TFC
223DAGS
2DAGS
0MGOCONN @ MH 3 O'CLOCK/OPEN
108.2TFC
225.6SAV
59.5TFC
0AMH18 0102
223SSS
225.6MGOCONN @ MH 3 O'CLOCK/OPEN
97.6CM
0MWL

Properties (6)

custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-05-06T23:15:36-07:00
documentation
PROPIPE
is_lateral_inspection
false