Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 10, 2021, 08:16 AM
  • 18 0089_18 0088_05102021_013343.mp4

Date
05/10/2021
W/O
891153
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00698
PipeID
P13908
Time
1:16 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8848
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_891153_TV18177_MAY2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0089
Downstream MH
18 0088
Dir. of Survey
Downstream
Length Surveyed
358.4 ft.
Total Length
358.4 ft.
Structural Index
2
Structural Quick
3M2N
Structural Rating
359
O&M Index
2
O&M Quick
2N00
O&M Rating
148
Overall Index
2
Overall Quick
Overall Rating
507
Pipe schematic from manhole 18 0089 to 18 0088
MH: 18 0089MH: 18 0088downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - ROACHES @ MH0 ft. AMH - Upstream Manhole, Survey Begins - 18 00892 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start178.7 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES178.7 ft. IS - Infiltration Stain, at 02 o'clock, within 8 inches of joint: YES205.9 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 12 to 03 o'clock, , within 8 inches of joint: YES243 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 12 to 01 o'clock, , within 8 inches of joint: YES259.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 8"277.3 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES277.3 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, at 11 o'clock, , within 8 inches of joint: YES355.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish356 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish356 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish358.4 ft. AMH - Downstream Manhole, Survey Ends - 18 0088358.4 ft. MGO - General Observation - CONN @MH 3 O'CLOCK/ACTIVE

Observation photos (7)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    178.7 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Infiltration Stain, at 02 o'clock, within 8 inches of joint: YES

    178.7 ft. - Infiltration Stain, at 02 o'clock, within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 12 to 03 o'clock,  , within 8 inches of joint: YES

    205.9 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 12 to 03 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 12 to 01 o'clock,  , within 8 inches of joint: YES

    243 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 12 to 01 o'clock, , within 8 inches of joint: YES

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    277.3 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, at 11 o'clock,  , within 8 inches of joint: YES

    277.3 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, at 11 o'clock, , within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
205.9DAE
2SSS
277.3CL
2SAV
178.7CL
277.3DAE
356DAGS
0MWM
0MWL
0MGOROACHES @ MH
358.4AMH18 0088
358.4MGOCONN @MH 3 O'CLOCK/ACTIVE
178.7IS
259.6TFC
2DAGS
243DAE
356SSS
0AMH18 0089
355.4SAV

Properties (6)

custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-05-10T01:16:45-07:00
documentation
PROPIPE
is_lateral_inspection
false