Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 13, 2021, 07:54 AM
  • 18 0085_18 0084_05132021_010418.mp4

Date
05/13/2021
W/O
891153
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13904
Time
12:54 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8864
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_891153_TV18177_MAY2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0085
Downstream MH
18 0084
Dir. of Survey
Downstream
Length Surveyed
282.1 ft.
Total Length
282.1 ft.
Structural Index
3
Structural Quick
3J2K
Structural Rating
287
O&M Index
2
O&M Quick
2J00
O&M Rating
112
Overall Index
2
Overall Quick
Overall Rating
399
Pipe schematic from manhole 18 0085 to 18 0084
MH: 18 0085MH: 18 0084downstream0 ft. MWL - Water Level, 25%of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 00850 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - ROACHES @ MH2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start108.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"112.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES166.8 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES180 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6"202.4 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES280 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish280 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish282 ft. MGO - General Observation - ROACHES @ MH282.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish282.1 ft. AMH - Downstream Manhole, Survey Ends - 18 0084

Observation photos (4)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    112.7 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    166.8 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    202.4 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (17)

DistanceCodeObservation
166.8FL
2SSS
0MWL
108.2TFC
2.1SAV
282.1SAV
112.7CL
0AMH18 0085
282.1AMH18 0084
282MGOROACHES @ MH
2DAGS
180TFC
280SSS
202.4CL
0MWM
0MGOROACHES @ MH
280DAGS

Properties (7)

additional_info
630138051221202
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-05-13T00:54:55-07:00
documentation
PROPIPE
is_lateral_inspection
false