Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 20, 2021, 07:00 AM
  • 18 0832_18 0831_05202021_004341.mp4

Date
05/20/2021
W/O
890885
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00708
PipeID
P20178
Time
12:00 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8872
Sewer Name
18 SO WHITTIER OUTFALL TR, SECT 6
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Routine Assessment
Project
WO_890885_TV18110_MAY2021
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0831
Downstream MH
18 0832
Dir. of Survey
Upstream
Length Surveyed
2.2 ft.
Total Length
2.2 ft.
Structural Index
1
Structural Quick
1100
Structural Rating
1
O&M Index
4
O&M Quick
5141
O&M Rating
11
Overall Index
3
Overall Quick
Overall Rating
12
Pipe schematic from manhole 18 0831 to 18 0832
MH: 18 0831MH: 18 0832upstream0 ft. MSA - Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH0.1 ft. CC - Crack Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES0.1 ft. LU - Alignment Up, 45 %0.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: NO2.2 ft. MWM - Water Mark, 100 %of cross sectional area2.2 ft. AMH - Downstream Manhole, Survey Begins - 18 0831 S2.2 ft. MWL - Water Level, 100 %of cross sectional area

Observation photos (2)

  • Crack Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.1 ft. - Crack Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH

    2.2 ft. - Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH

Observations (7)

DistanceCodeObservation
0MWM
2.1CC
2.2MSAVIEW OF U/S SIPHON FROM D/S MH
0AMH18 0831 S
2.1LU
2DAGS
0MWL

Properties (7)

additional_info
630138051921202
custom_field_three
CRACK
custom_field_two
5
customer
1
datetime
2021-05-20T00:00:54-07:00
documentation
PROPIPE
is_lateral_inspection
false