Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 20, 2021, 07:00 AM
  • 18 0832_18 0831_05202021_000352.mp4

Date
05/20/2021
W/O
890885
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00708
PipeID
P20178
Time
12:00 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8872
Sewer Name
18 SO WHITTIER OUTFALL TR, SECT 6
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Routine Assessment
Project
WO_890885_TV18110_MAY2021
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0832
Downstream MH
18 0831
Dir. of Survey
Downstream
Length Surveyed
2.2 ft.
Total Length
2.2 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
4
O&M Quick
5141
O&M Rating
11
Overall Index
3
Overall Quick
Overall Rating
13
Pipe schematic from manhole 18 0832 to 18 0831
MH: 18 0832MH: 18 0831downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 0832 S0 ft. MWL - Water Level, 100 %of cross sectional area0 ft. MWM - Water Mark, 100 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO2.1 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO2.1 ft. LU - Alignment Up, 45 %2.2 ft. MSA - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

Observation photos (2)

  • Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: NO

    2.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO

  • Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

    2.2 ft. - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

Observations (7)

DistanceCodeObservation
2.1DAGS
0AMH18 0832 S
2.1LU
0MWL
2SSS
0MWM
2.2MSAVIEW OF D/S SIPHON FROM U/S MH

Properties (7)

additional_info
630138051921202
custom_field_three
CRACK
custom_field_two
5
customer
1
datetime
2021-05-20T00:00:54-07:00
documentation
PROPIPE
is_lateral_inspection
false