- Date
- 05/19/2021
- W/O
- 890885
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00708
- PipeID
- P14699
- Time
- 10:55 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8872
- Sewer Name
- 18 SO WHITTIER OUTFALL TR, SECT 6
- City
- SANTA FE SPRINGS
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- WO_890885_TV18110_MAY2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 18 0835
- Downstream MH
- 18 0836
- Dir. of Survey
- Upstream
- Length Surveyed
- 482.6 ft.
- Total Length
- 482.6 ft.
- Structural Index
- 2
- Structural Quick
- 3Q2S
- Structural Rating
- 478
- O&M Index
- 2
- O&M Quick
- 2R00
- O&M Rating
- 192
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 670
Pipe schematic from manhole 18 0835 to 18 0836 Observation photos (7)

2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

11.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

41.6 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

254.7 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

326.5 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

341.8 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

350.6 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES