Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 18, 2021, 09:15 AM
  • 05 1006_05 1005_05182021_022916.mp4

Date
05/18/2021
W/O
890934
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00421
PipeID
P06238
Time
2:15 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8961
Sewer Name
05 AVIATION BOULEVARD TRUNK
City
EL SEGUNDO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_890934_TV05252_MAY2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
10 in.
Upstream MH
05 1005
Downstream MH
05 1006
Dir. of Survey
Upstream
Length Surveyed
334.5 ft.
Total Length
334.5 ft.
Structural Index
3
Structural Quick
3L00
Structural Rating
189
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
189
Pipe schematic from manhole 05 1005 to 05 1006
MH: 05 1005MH: 05 1006upstream0 ft. MGO - General Observation - CONNECTION AT MH, 3 AND 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 05 10061.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish56.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"132.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"210 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8"282.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"312.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start322.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES334.5 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK334.5 ft. MWM - Water Mark, 15 %of cross sectional area334.5 ft. MWL - Water Level, 5 %of cross sectional area334.5 ft. AMH - Downstream Manhole, Survey Begins - 05 1005

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    12.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    22.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
0MGOCONNECTION AT MH, 3 O'CLOCK
52.3TFC
0MWM
277.8TFC
124.5TF
12.3CM
334.5MGOCONNECTION AT MH, 3 AND 9 O'CLOCK
201.9TFC
22.3CM
333.3CM
0MWL
334.5AMH05 1006
0AMH05 1005

Properties (6)

custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2021-05-18T02:15:04-07:00
documentation
PRO PIPE
is_lateral_inspection
false