- Date
- 05/10/2021
- W/O
- 891398
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00698
- PipeID
- P13890
- Time
- 11:16 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8862
- Sewer Name
- 18 SANTA FE STREET TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_891398_TV18083_MAY2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 18 0075
- Downstream MH
- 18 0074
- Dir. of Survey
- Downstream
- Length Surveyed
- 246.2 ft.
- Total Length
- 246.2 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 5
Pipe schematic from manhole 18 0075 to 18 0074 Observation photos (3)

5.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

17.8 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

167.6 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"