Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 11, 2021, 06:28 AM
  • 18 0074_18 0073_05102021_233903.mp4

Date
05/10/2021
W/O
891398
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13889
Time
11:28 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8862
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_891398_TV18083_MAY2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0074
Downstream MH
18 0073
Dir. of Survey
Downstream
Length Surveyed
308.6 ft.
Total Length
308.6 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 18 0074 to 18 0073
MH: 18 0074MH: 18 0073downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 00740 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area3.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start16.9 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"89.8 ft. TS - Tap Saddle, at 11 o'clock, -, within 8 inches of joint: NO, 6"115.9 ft. TSI - Tap Saddle Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"125.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"215.7 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"228.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"293.8 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"308.6 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK308.6 ft. AMH - Downstream Manhole, Survey Ends - 18 0073308.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (6)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    16.9 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Saddle, at 11 o'clock, -, within 8 inches of joint: NO, 6"

    89.8 ft. - Tap Saddle, at 11 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Saddle Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

    115.9 ft. - Tap Saddle Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

  • Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    215.7 ft. - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    293.8 ft. - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

Observations (15)

DistanceCodeObservation
89.8TS
0AMH18 0074
308.6MGOCONNECTION AT MH 3 O'CLOCK
115.9TSI
0MGOCONNECTION AT MH 9 O'CLOCK
0MWL
3.8SAV
308.6AMH18 0073
16.9TB
215.7TSA
0MWM
228.3TF
125.1TF
308.6SAV
293.8TSA

Properties (6)

additional_info
630138051021202
custom_field_two
3
customer
1
datetime
2021-05-10T23:28:39-07:00
documentation
PROPIPE
is_lateral_inspection
false