Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 5, 2021, 07:07 AM
  • 18 0114_18 0113_05052021_001825.mp4

Date
05/05/2021
W/O
891398
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13934
Time
12:07 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8859
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_891398_TV18083_MAY2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0113
Downstream MH
18 0114
Dir. of Survey
Upstream
Length Surveyed
111.7 ft.
Total Length
111.7 ft.
Structural Index
3
Structural Quick
3F00
Structural Rating
99
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
99
Pipe schematic from manhole 18 0113 to 18 0114
MH: 18 0113MH: 18 0114upstream0 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 18 01140 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish6.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"12.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"26.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start33.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES40.5 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES53.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"53.7 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES59.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"64.8 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES71 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES85.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES102.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"108.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"108.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start111.7 ft. AMH - Downstream Manhole, Survey Begins - 18 0113111.7 ft. MWL - Water Level, 15 %of cross sectional area111.7 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK111.7 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (8)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    25.8 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    40.7 ft. - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    46.9 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    58 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    71.2 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    78.1 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    85.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (21)

DistanceCodeObservation
3.3TFC
0AMH18 0113
3.3SAV
58.1TFA
46.9FL
25.8FL
71.2FL
0MWL
0MGOCONNECTION AT THE MH 9 OC'LOCK
111.7SAV
0MWM
58CM
8.9TF
85.6CM
111.7AMH18 0114
104.9TF
40.7FL
78.1FL
111.7CM
99.3TF
52.3TF

Properties (7)

additional_info
630074050421201
custom_field_three
AGGREGATE VISIBLE/MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-05-05T00:07:43-07:00
documentation
PROPIPE
is_lateral_inspection
false