Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 5, 2021, 05:01 AM
  • 18 0111_18 0110_05042021_221446.mp4

Date
05/04/2021
W/O
891398
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13931
Time
10:01 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8859
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_891398_TV18083_MAY2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0111
Downstream MH
18 0110
Dir. of Survey
Downstream
Length Surveyed
227.1 ft.
Total Length
227.1 ft.
Structural Index
3
Structural Quick
423I
Structural Rating
160
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
160
Pipe schematic from manhole 18 0111 to 18 0110
MH: 18 0111MH: 18 0110downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - 18 01110 ft. MWL - Water Level, 15 %of cross sectional area2.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start5.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES37 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"38.5 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES43.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"63 ft. FM - Fracture Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES75 ft. CL - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES85.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"91.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"102.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES117.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES137.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"143.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"154.5 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES173.1 ft. FM - Fracture Multiple, from 11 to 12 o'clock, within 8 inches of joint: YES186.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"192.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"227 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish227.1 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK CAPPED227.1 ft. AMH - Downstream Manhole, Survey Ends - 18 0110

Observation photos (9)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    5.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    38.5 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES

    63 ft. - Fracture Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

    75 ft. - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    102.8 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    117.8 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    154.5 ft. - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 11 to 12 o'clock, within 8 inches of joint: YES

    173.1 ft. - Fracture Multiple, from 11 to 12 o'clock, within 8 inches of joint: YES

Observations (24)

DistanceCodeObservation
38.5FL
0MWM
143.6TFC
75CL
173.1FM
85.7TF
43.1TFC
192.6TFC
63FM
137.4TF
0MGOCONNECTION AT THE MH 3 OC'LOCK
102.8FL
5.2FL
227.1MGOCONNECTION AT THE MH 3 OC'LOCK CAPPED
0AMH18 0111
227.1AMH18 0110
227SAV
91.9TFC
117.8FL
186.6TF
0MWL
154.5FL
37TF
2.8SAV

Properties (7)

additional_info
630074050421201
custom_field_three
AGGREGATE VISIBLE/MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-05-04T22:01:05-07:00
documentation
PROPIPE
is_lateral_inspection
false