Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 5, 2021, 05:21 AM
  • 18 0110_18 0109_05042021_222704.mp4

Date
05/04/2021
W/O
891398
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13930
Time
10:21 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8859
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_891398_TV18083_MAY2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0110
Downstream MH
18 0109
Dir. of Survey
Downstream
Length Surveyed
41 ft.
Total Length
41 ft.
Structural Index
3
Structural Quick
3822
Structural Rating
28
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
28
Pipe schematic from manhole 18 0110 to 18 0109
MH: 18 0110MH: 18 0109downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 01100 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK CAPPED2.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6.6 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES18.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES30.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"38.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"41 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish41 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK41 ft. AMH - Downstream Manhole, Survey Ends - 18 0109

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    6.6 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    18.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
0MWL
6.6CL
38.7TFC
0AMH18 0110
41SAV
0MWM
2.6SAV
41MGOCONNECTION AT THE MH 3 OC'LOCK
18.6CL
30.6TFA
0MGOCONNECTION AT THE MH 3 OC'LOCK CAPPED
41AMH18 0109

Properties (7)

additional_info
630074050421201
custom_field_three
AGGREGATE VISIBLE/MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-05-04T22:21:07-07:00
documentation
PROPIPE
is_lateral_inspection
false