Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 7, 2021, 09:45 AM
  • 18 1108_18 0093_05072021_025627.mp4

Date
05/07/2021
W/O
891398
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00698
PipeID
P13913
Time
2:45 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8846
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_891398_TV18083_MAY2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 1108
Downstream MH
18 0093
Dir. of Survey
Downstream
Length Surveyed
340.5 ft.
Total Length
340.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 18 1108 to 18 0093
MH: 18 1108MH: 18 0093downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 11080 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area4.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start51.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 8"255.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 8"259.2 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 8"340.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish340.5 ft. MGO - General Observation - CONNECTION AT MH 12 O'CLOCK340.5 ft. AMH - Downstream Manhole, Survey Ends - 18 0093

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 8"

    259.2 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 8"

Observations (11)

DistanceCodeObservation
259.2TB
340.5MGOCONNECTION AT MH 12 O'CLOCK
4.7SAV
0MWM
0AMH18 1108
51.5TF
0MGOCONNECTION AT MH 3 O'CLOCK
340.5AMH18 0093
255.1TFC
0MWL
340.1SAV

Properties (6)

custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-05-07T02:45:11-07:00
documentation
PROPIPE
is_lateral_inspection
false