18 1248_18 0086_05102021_021236.mp4
3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
26.1 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES
26.1 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 02 to 04 o'clock, , within 8 inches of joint: YES
59.3 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES
77.6 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 03 to 04 o'clock, , within 8 inches of joint: YES
77.6 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES
95.9 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES
108.4 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start
| Distance | Code | Observation |
|---|---|---|
| 0 | MWL | — |
| 59.3 | DAE | — |
| 26.1 | CL | — |
| 112.7 | TFC | — |
| 312.2 | AMH | 18 0086 |
| 3 | SAV | — |
| 95.9 | DAE | — |
| 212.6 | TFC | — |
| 0 | MWM | — |
| 77.6 | DAE | — |
| 0 | AMH | 18 1248 |
| 312.2 | MGO | CONNECTION AT MH 3 O'CLOCK |
| 309.8 | DAE | — |
| 108.4 | DAE | — |
| 0 | MGO | CONNECTION AT MH 9 O'CLOCK |
| 309.8 | SAV | — |
| 77.6 | CL | — |
| 26.1 | DAE | — |