Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 14, 2021, 08:57 AM
  • 21 0333_H 0947_05142021_021113.mp4

Date
05/14/2021
W/O
890915
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00783
PipeID
P15534
Time
1:57 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8956
Sewer Name
21 RAILROAD STREET TRUNK
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
34
Purpose
Routine Assessment
Project
RFIR_WO_890915_TV21111_MAY2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
21 0333
Downstream MH
H 0947
Dir. of Survey
Downstream
Length Surveyed
249.1 ft.
Total Length
249.1 ft.
Structural Index
3
Structural Quick
3623
Structural Rating
24
O&M Index
2
O&M Quick
2300
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
30
Pipe schematic from manhole 21 0333 to H 0947
MH: 21 0333MH: H 0947downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 21 033311.7 ft. CM - Crack Multiple, from 04 to 07 o'clock, within 8 inches of joint: YES48.4 ft. TBC - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"72.7 ft. CM - Crack Multiple, from 04 to 06 o'clock, within 8 inches of joint: YES77.7 ft. CS - Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES113.5 ft. FS - Fracture Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES124.5 ft. TBC - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"148.6 ft. CS - Crack Spiral, from 04 to 05 o'clock, within 8 inches of joint: YES158.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES188.8 ft. CM - Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES200.1 ft. TBC - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"238.9 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES244.1 ft. FS - Fracture Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES248.9 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK248.9 ft. MGO - General Observation - CONNECTION AT MH 12 OCLOCK CAPPED249.1 ft. AMH - Downstream Manhole, Survey Ends - H 0947

Observation photos (12)

  • Crack Multiple, from 04 to 07 o'clock, within 8 inches of joint: YES

    11.7 ft. - Crack Multiple, from 04 to 07 o'clock, within 8 inches of joint: YES

  • Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"

    48.4 ft. - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"

  • Crack Multiple, from 04 to 06 o'clock, within 8 inches of joint: YES

    72.7 ft. - Crack Multiple, from 04 to 06 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

    77.7 ft. - Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES

    113.5 ft. - Fracture Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES

  • Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"

    124.5 ft. - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"

  • Crack Spiral, from 04 to 05 o'clock, within 8 inches of joint: YES

    148.6 ft. - Crack Spiral, from 04 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    158.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES

    188.8 ft. - Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"

    200.1 ft. - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    238.9 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES

    244.1 ft. - Fracture Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES

Observations (18)

DistanceCodeObservation
249.1AMHH 0947
248.9MGOCONNECTION AT MH, 3 O'CLOCK
113.5FS
158.5CM
124.5TBC
11.7CM
148.6CS
238.9CL
0MWM
188.8CM
72.7CM
0MWL
248.9MGOCONNECTION AT MH 12 OCLOCK CAPPED
200.1TBC
77.7CS
48.4TBC
244.1FS
0AMH21 0333

Properties (6)

custom_field_three
MULTIPLE CRACKS, FRACTURES
custom_field_two
3
customer
1
datetime
2021-05-14T01:57:31-07:00
documentation
PRO PIPE
is_lateral_inspection
false