- Date
- 05/27/2021
- W/O
- 0890933
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00155
- PipeID
- P09989
- Time
- 10:21 AM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1824
- Sewer Name
- D JOINT OUTFALL D - UNIT 5
- City
- GARDENA
- Loc. details
- Other
- Location Code
- Z
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 20
- Purpose
- Capital Improvement Program Assesment
- Project
- 20210527SHO_JOINT_OUTFALL_D_UNIT_5
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 42 in.
- Upstream MH
- D 0089
- Downstream MH
- D 0088
- Dir. of Survey
- Downstream
- Length Surveyed
- 463.4 ft.
- Total Length
- 463.4 ft.
- Structural Index
- 4
- Structural Quick
- 5231
- Structural Rating
- 15
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 15
Pipe schematic from manhole D 0089 to D 0088 Observation photos (1)

13.8 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start