Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 14, 2021, 06:13 AM
  • 18 0279_18 0278_05132021_233417.mp4

Date
05/13/2021
W/O
891439
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00702
PipeID
P14107
Time
11:13 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8867
Sewer Name
18 SHOEMAKER AVENUE TRUNK
City
SHOEMAKER AVE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
30
Purpose
Routine Assessment
Project
RFIR_WO_891439_TV18148_MAY2021
Sewer Type
Gravity
Material
NRCP
Shape
Square
Height
15 in.
Width
15 in.
Upstream MH
18 0279
Downstream MH
18 0278
Dir. of Survey
Downstream
Length Surveyed
134.9 ft.
Total Length
134.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 18 0279 to 18 0278
MH: 18 0279MH: 18 0278downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 02790 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area3.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start9.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"12.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"26 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"55.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"58.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"106.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"110.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"134.9 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK134.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish134.9 ft. AMH - Downstream Manhole, Survey Ends - 18 0278

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
26TF
0AMH18 0279
9.9TFC
58.6TFC
134.9MGOACTIVE CONNECTION AT MH 9 O'CLOCK
3.1SAV
106.9TFC
55.3TFC
134.9SAV
0MWM
0MWL
110.6TFC
12.6TFC
134.9AMH18 0278

Properties (7)

additional_info
630138051321202
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-05-13T23:13:38-07:00
documentation
PROPIPE
is_lateral_inspection
false