Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 13, 2021, 06:49 AM
  • 02 0366A_02 0366_05132021_000521.mp4

Date
05/12/2021
W/O
890910
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00250
PipeID
P02681
Time
11:49 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8907
Sewer Name
02 DOWNEY AVENUE EXTENSION TRUNK
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_890910_TV02126_MAY2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0366A
Downstream MH
02 0366
Dir. of Survey
Downstream
Length Surveyed
301.1 ft.
Total Length
301.1 ft.
Structural Index
2
Structural Quick
513H
Structural Rating
255
O&M Index
2
O&M Quick
322L
O&M Rating
136
Overall Index
2
Overall Quick
Overall Rating
391
Pipe schematic from manhole 02 0366A to 02 0366
MH: 02 0366AMH: 02 0366downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - ROACHES @ MH0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 02 0366A2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start14.7 ft. TBD - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: YES, 4" - BROKEN CONN/OFFSET/ACTIVE14.7 ft. HVV - Hole Void Visible, from 12 to 03 o'clock, within 8 inches of joint: YES15.2 ft. MGP - General Photograph - HOLE VOID VISIBLE21.7 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"40.5 ft. CM - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES64.6 ft. TBD - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: YES, 4", 6" - CAPPED75.8 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"81.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start111.6 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6" - OFFSET CONN/OPEN127.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN162.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"174.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN212.4 ft. TBI - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 1", 6" - ACTIVE228 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"263.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN274.4 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"299 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish299 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish299 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish301.1 ft. AMH - Downstream Manhole, Survey Ends - 02 0366301.1 ft. MGO - General Observation - ROACHES @ MH

Observation photos (7)

  • General Observation - ROACHES @ MH

    0 ft. - General Observation - ROACHES @ MH

  • Hole Void Visible, from 12 to 03 o'clock, within 8 inches of joint: YES

    14.7 ft. - Hole Void Visible, from 12 to 03 o'clock, within 8 inches of joint: YES

  • General Photograph - HOLE VOID VISIBLE

    15.2 ft. - General Photograph - HOLE VOID VISIBLE

  • Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

    40.5 ft. - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    81.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 1", 6" - ACTIVE

    212.4 ft. - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 1", 6" - ACTIVE

  • General Observation - ROACHES @ MH

    301.1 ft. - General Observation - ROACHES @ MH

Observations (28)

DistanceCodeObservation
299DAGS
0MWM
64.6TBDCAPPED
162.3TFA
0MWL
263.1TBOPEN
299SSS
40.5CM
75.8TBC
14.7TBDBROKEN CONN/OFFSET/ACTIVE
301.1AMH02 0366
301.1MGOROACHES @ MH
81.7CM
228TBC
21.7TBC
127.1TBOPEN
0MGOROACHES @ MH
15.2MGPHOLE VOID VISIBLE
212.4TBIACTIVE
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
14.7HVV
2SSS
0AMH02 0366A
174.1TBOPEN
2DAGS
111.6TFDOFFSET CONN/OPEN
274.4TBC
299CM

Properties (7)

additional_info
630069051221201
custom_field_three
HOLE VOID VISIBLE/MULTIPLE CRACKS
custom_field_two
1
customer
1
datetime
2021-05-12T23:49:47-07:00
documentation
PRO PIPE
is_lateral_inspection
false