Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 26, 2021, 08:09 AM
  • 22 0484_22 0483_04262021_011800.mp4

Date
04/26/2021
W/O
886009
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00800
PipeID
P16823
Time
1:09 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8744
Sewer Name
22 COVINA CONNECTION EXTENSION TRUNK
City
COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
31
Purpose
Routine Assessment
Project
RFIR_WO_886009_TV22031_APR2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
22 0484
Downstream MH
22 0483
Dir. of Survey
Downstream
Length Surveyed
157.2 ft.
Total Length
157.2 ft.
Structural Index
3
Structural Quick
413E
Structural Rating
159
O&M Index
2
O&M Quick
2E00
O&M Rating
62
Overall Index
2
Overall Quick
Overall Rating
221
Pipe schematic from manhole 22 0484 to 22 0483
MH: 22 0484MH: 22 0483downstream0 ft. MGO - General Observation - CONN @ MH 3 OC'LOCK/ACTIVE0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 04842 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.6 ft. MGO - General Observation - 70% MAG COAT6.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"10 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"58 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"61.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"106.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"109.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"150.9 ft. FM - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES155 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish155 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish157.2 ft. AMH - Downstream Manhole, Survey Ends - 22 0483157.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

    150.9 ft. - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
157.2AMH22 0483
109.4TFC
106.4TFC
0MGOCONN @ MH 3 OC'LOCK/ACTIVE
155SSS
0MWM
155DAGS
2DAGS
150.9FM
157.2SAV
10TFC
58TFC
2.6SAV
0MWL
2SSS
0AMH22 0484
6.8TFC
2.6MGO70% MAG COAT
61.2TFC

Properties (7)

additional_info
630074042621001
custom_field_three
AGGREGATE VISIBLE/MULTIPLE fracture
custom_field_two
3
customer
1
datetime
2021-04-26T01:09:33-07:00
documentation
PROPIPE
is_lateral_inspection
false