Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 19, 2021, 10:41 AM
  • 18 0964A_18 0963_5192021_034622.mp4

Date
05/19/2021
W/O
0885949
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00716
PipeID
P14813
Time
3:41 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1811R
Sewer Name
18 WORSHAM CREEK TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
11
Purpose
Maintenance Related
Project
20210518MDM_WORSHAM_CREEK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
9.5 in.
Upstream MH
18 0964A
Downstream MH
18 0963
Dir. of Survey
Downstream
Length Surveyed
356.9 ft.
Total Length
356.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 18 0964A to 18 0963
MH: 18 0964AMH: 18 0963downstream0 ft. AMH - Upstream Manhole, Survey Begins - 3:50AM0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area92 ft. RMC - Roots Medium Connection, from 01 to 04 o'clock, 35 %, within 8 inches of joint: YES356.9 ft. AMH - Downstream Manhole, Survey Ends - 4:25AM

Observation photos (1)

  • Roots Medium Connection, from 01 to 04 o'clock, 35 %, within 8 inches of joint: YES

    92 ft. - Roots Medium Connection, from 01 to 04 o'clock, 35 %, within 8 inches of joint: YES

Observations (5)

DistanceCodeObservation
0AMH3:50AM
356.9AMH4:25AM
0MWM
92RMC
0MWL

Properties (6)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2021-05-19T03:41:48-07:00
documentation
MARTIN,OLIVER 111,CASTILLO,RUVALCABA
is_lateral_inspection
false
lining