Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 18, 2021, 11:16 AM
  • 18 0966_18 0965_5182021_041811.mp4

Date
05/18/2021
W/O
0885949
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00716
PipeID
P14816
Time
4:16 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1811R
Sewer Name
18 WORSHAM CREEK TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
11
Purpose
Maintenance Related
Project
20210518MDM_WORSHAM_CREEK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
9.5 in.
Upstream MH
18 0965
Downstream MH
18 0966
Dir. of Survey
Upstream
Length Surveyed
182 ft.
Total Length
182 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
1
Overall Quick
Overall Rating
1
Pipe schematic from manhole 18 0965 to 18 0966
MH: 18 0965MH: 18 0966upstream0 ft. AMH - Upstream Manhole, Survey Ends - 4:45AM86.3 ft. RFC - Roots Fine Connection, from 11 to 01 o'clock, within 8 inches of joint: NO - 1%182 ft. AMH - Upstream Manhole, Survey Begins - 4:25AM182 ft. MWL - Water Level, 5 %of cross sectional area182 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active182 ft. MWM - Water Mark, 20 %of cross sectional area

Observations (6)

DistanceCodeObservation
0AMH4:25AM
182AMH4:45AM
0MWL
0MGOConn. @ Mh, 9 O' Clock. Active
0MWM
95.7RFC1%

Properties (6)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2021-05-18T04:16:19-07:00
documentation
MARTIN,CASTILLO,RUVALCABA
is_lateral_inspection
false
lining
PVCP