A 0020_B 0929_5222021_015547.mp4
1 ft. - General Observation - MH CONN AT 9:00 LINER HAS FALLEN OFF PIPE AND HANGING
1 ft. - General Observation - LARGE SEPRATED SECTTION OF LINER ON MH WALL 3:00 IN FLOW
2 ft. - General Observation - 70% TILES MISSING
2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE AREAS OF MISSING TILES
2 ft. - General Observation - OLD MAG COAT80%
32.5 ft. - General Observation - 100% TILES IN PLACE UNDER MAG COAT
187.2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG GREASE COATED
470.5 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG SREAS MISSING TILES
609.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
| Distance | Code | Observation |
|---|---|---|
| 609.6 | SRC | CIRCUM REBAR |
| 639.1 | SSS | BLISTERING PEELING CONCRETE UNDER MAG COAT |
| 1 | MGO | VEIW 3:00 INCOMING LINE APPEARS ACTIVE |
| 0 | MWM | — |
| 0 | MWL | — |
| 470.5 | SAM | SEVERE AGG SREAS MISSING TILES |
| 62.1 | MGO | POSSIBLE 70% MISSING TILES START |
| 639.1 | MGO | MISSING TILKES 70% POSSIBLE UNDER MAG COAT |
| 133.3 | MGO | MISSING TILES 20% |
| 187.2 | SAM | SEVERE AGG GREASE COATED |
| 0 | AMH | 1:45AM |
| 639.8 | AMH | 2:50AM |
| 2 | MGO | 70% TILES MISSING |
| 639.1 | SAM | SEVERE AGG |
| 2 | SSS | BLISTERING PEELING CONCRETE AREAS OF MISSING TILES |
| 2 | SAM | SEVERE AGG AREAS OF MISSING TILES |
| 2 | MGO | OLD MAG COAT80% |
| 51.6 | MGO | 40% MISSING TILES UNDER MAG COAT |
| 1 | MGO | MH CONN AT 9:00 LINER HAS FALLEN OFF PIPE AND HANGING |
| 639.1 | SRC | CIRCUM REBAR |
| 32.5 | MGO | 100% TILES IN PLACE UNDER MAG COAT |
| 0 | MGO | Conn. @ Mh, 9 O' Clock. OPEN |
| 1 | MGO | LARGE SEPRATED SECTTION OF LINER ON MH WALL 3:00 IN FLOW |