Search
Uploads
Inspections
Wastewater/Activity/PacpInspection/1.0
May 19, 2021, 03:47 PM
A 1310_A 1309_5192021_091338.mp4
Date
05/19/2021
W/O
TEST
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z01211
PipeID
P26418
Time
8:47 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
—
Pre-Cleaning
Not Known
Media Label
TEST TEST
Sewer Name
A JOA-1A GRIDLEY ROAD INTERCEPTOR
City
CERRITOS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
01
Purpose
Z
Project
20210519SHO_JOA_1A_GRIDLEY_ROAD_INTERCEPTOR
Material
FRPP
Shape
Circular
Height
20 in.
Upstream MH
A 1310
Downstream MH
A 1309
Dir. of Survey
Downstream
Length Surveyed
44.1 ft.
Total Length
44.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
—
Overall Rating
4
Pipe schematic from manhole A 1310 to A 1309
MH: A 1310
MH: A 1309
downstream
0 ft.
0 ft. AMH - Upstream Manhole, Survey Begins - 1310
0 ft. MWL - Water Level, 20 %of cross sectional area
0 ft. MWM - Water Mark, 35 %of cross sectional area
8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start
44.1 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS
All inspections of P26418
Work order TEST
Observations (6)
Distance
Code
Observation
0
—
—
0
AMH
1310
0
MWL
—
0
MWM
—
8
DAGS
—
44.1
DSZ
DEBRIS
Properties (8)
additional_info
JUST A TEST RUN
custom_field_three
NOT A REAL INSPECTION, TEST RUN
custom_field_two
5
customer
LACSD
datetime
2021-05-19T08:47:27-07:00
documentation
OBREGON, SHADLER, IGNACIO
is_lateral_inspection
false
year_laid
20121121