Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 17, 2021, 08:01 AM
  • 08 0559_08 0558_03172021_011649.mp4

Date
03/17/2021
W/O
879969
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00015
PipeID
P00144
Time
1:01 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8703
Sewer Name
08 MAIN STREET RELIEF TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
07
Purpose
Routine Assessment
Project
WO_879969_TV08024_MAR2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
42 in.
Upstream MH
08 0559
Downstream MH
08 0558
Dir. of Survey
Downstream
Length Surveyed
608.6 ft.
Total Length
608.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 08 0559 to 08 0558
MH: 08 0559MH: 08 0558downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 05590 ft. MWL - Water Level, 10 %of cross sectional area3.4 ft. MGO - General Observation - MAG COAT238.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"608.6 ft. AMH - Downstream Manhole, Survey Ends - 08 0558

Observations (6)

DistanceCodeObservation
238.4TFA
3.4MGOMAG COAT
0MWM
0AMH08 0559
608.6AMH08 0558
0MWL

Properties (8)

additional_info
630074031621201
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2021-03-17T01:01:15-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
27219