Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 11, 2021, 06:01 AM
  • 08 0123_08 0122_03102021_234759.mp4

Date
03/10/2021
W/O
879969
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00015
PipeID
P00173
Time
10:01 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8500
Sewer Name
08 MAIN STREET RELIEF TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
WO_879969_TV08024_MAR2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
27 in.
Upstream MH
08 0123
Downstream MH
08 0122
Dir. of Survey
Downstream
Length Surveyed
596.1 ft.
Total Length
596.1 ft.
Structural Index
3
Structural Quick
3V00
Structural Rating
345
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
345
Pipe schematic from manhole 08 0123 to 08 0122
MH: 08 0123MH: 08 0122downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 01230 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWL - Water Level, 15 %of cross sectional area6.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"20.8 ft. MGO - General Observation - MAG COAT20.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start63.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"127.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"182.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"246.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"302.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"358.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"421.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"477.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"541.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"596.1 ft. AMH - Downstream Manhole, Survey Ends - 08 0122596.1 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK596.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    20.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (19)

DistanceCodeObservation
302.3TFC
596.1AMH08 0122
358.1TF
0MWM
63.4TFC
596.1MGOCONNECTION AT THE MH 3 OC'LOCK
0AMH08 0123
0MGOCONNECTION AT THE MH 3 OC'LOCK
421.4TFC
20.8MGOMAG COAT
477.4TFC
246.4TFC
20.8SAV
541.2TFC
0MWL
182.9TF
6.8TFC
596.1SAV
127.1TFC

Properties (7)

additional_info
630074031021201
custom_field_three
NO SEVERE DEFECTS
custom_field_two
3
customer
1
datetime
2021-03-10T22:01:05-08:00
documentation
PROPIPE
is_lateral_inspection
false