Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 16, 2021, 10:20 AM
  • 08 0106_08 0105_03162021_032805.mp4

Date
03/16/2021
W/O
879969
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00015
PipeID
P00154
Time
3:20 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8702
Sewer Name
08 MAIN STREET RELIEF TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
WO_879969_TV08024_MAR2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
39 in.
Upstream MH
08 0106
Downstream MH
08 0105
Dir. of Survey
Downstream
Length Surveyed
175.8 ft.
Total Length
175.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 08 0106 to 08 0105
MH: 08 0106MH: 08 0105downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 01063.3 ft. MGO - General Observation - MAG COAT35.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"105 ft. MGO - General Observation - POSSIBLE MH @ 2 O'CLOCK161.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"175.8 ft. AMH - Downstream Manhole, Survey Ends - 08 0105

Observations (8)

DistanceCodeObservation
0MWL
175.8AMH08 0105
3.3MGOMAG COAT
0MWM
161.4TFC
105MGOPOSSIBLE MH @ 2 O'CLOCK
0AMH08 0106
35.1TFC

Properties (7)

additional_info
630074031521201
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2021-03-16T03:20:52-07:00
documentation
PROPIPE
is_lateral_inspection
false