Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 4, 2021, 05:11 AM
  • 29 0006_29 0005_05032021_223246.mp4

Date
05/03/2021
W/O
890798
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00849
PipeID
P17680
Time
10:11 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8855
Sewer Name
29 SIGNAL HILL OUTFALL TRUNK
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
19
Purpose
Routine Assessment
Project
WO_890798_TV29087_MAY2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
29 0005
Downstream MH
29 0006
Dir. of Survey
Upstream
Length Surveyed
700.2 ft.
Total Length
700.2 ft.
Structural Index
3
Structural Quick
3[00
Structural Rating
417
O&M Index
3
O&M Quick
3121
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
422
Pipe schematic from manhole 29 0005 to 29 0006
MH: 29 0005MH: 29 0006upstream0 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 29 0006110.6 ft. IW - Infiltration Weeper, from 08 to 04 o'clock, within 8 inches of joint: YES134.9 ft. ID - Infiltration Dripper, from 10 to 02 o'clock, within 8 inches of joint: YES697.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start698.1 ft. MGO - General Observation - MAG COAT700.1 ft. MWM - Water Mark, 20 %of cross sectional area700.2 ft. AMH - Downstream Manhole, Survey Begins - 29 0005700.2 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK700.2 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Infiltration Dripper, from 10 to 02 o'clock, within 8 inches of joint: YES

    565.3 ft. - Infiltration Dripper, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Infiltration Weeper, from 08 to 04 o'clock, within 8 inches of joint: YES

    589.6 ft. - Infiltration Weeper, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
0AMH29 0005
700.2SAV
2.9SAV
700.2AMH29 0006
2.1MGOMAG COAT
0MGOCONNECTION AT THE MH 3 OC'LOCK
0.1MWM
565.3ID
0MWL
589.6IW

Properties (7)

additional_info
630074050321201
custom_field_three
INFILTRATION
custom_field_two
3
customer
1
datetime
2021-05-03T22:11:09-07:00
documentation
PROPIPE
is_lateral_inspection
false