Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 21, 2021, 06:36 AM
  • 15 1175_15 1174_04202021_234242.mp4

Date
04/20/2021
W/O
885831
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01185
PipeID
P26102
Time
11:36 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8783
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTION 2 RELIEF EXTENSION
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
02
Purpose
Routine Assessment
Project
WO_885831_TV15115_APR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 1175
Downstream MH
15 1174
Dir. of Survey
Downstream
Length Surveyed
153.1 ft.
Total Length
153.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2E00
O&M Rating
60
Overall Index
2
Overall Quick
Overall Rating
60
Pipe schematic from manhole 15 1175 to 15 1174
MH: 15 1175MH: 15 1174downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 11750 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start151.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish153.1 ft. AMH - Downstream Manhole, Survey Ends - 15 1174

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
0MWM
153.1AMH15 1174
0AMH15 1175
2DAGS
151.5DAGS
0MWL

Properties (8)

additional_info
630069042021201
custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2021-04-20T23:36:45-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
39867