Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 21, 2021, 07:36 AM
  • 15 1172_15 1171_04212021_004948.mp4

Date
04/21/2021
W/O
885831
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01185
PipeID
P26099
Time
12:36 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8783
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTION 2 RELIEF EXTENSION
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
Routine Assessment
Project
WO_885831_TV15115_APR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 1172
Downstream MH
15 1171
Dir. of Survey
Downstream
Length Surveyed
421.3 ft.
Total Length
421.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2P00
O&M Rating
168
Overall Index
2
Overall Quick
Overall Rating
168
Pipe schematic from manhole 15 1172 to 15 1171
MH: 15 1172MH: 15 1171downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 11720 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start419.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish421.3 ft. AMH - Downstream Manhole, Survey Ends - 15 1171

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
0AMH15 1172
0MWL
421.3AMH15 1171
419.6DAGS
2DAGS
0MWM

Properties (8)

additional_info
630069042021201
custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2021-04-21T00:36:06-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
39867