Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 21, 2021, 10:06 AM
  • 15 0597_15 0596_04212021_032439.mp4

Date
04/21/2021
W/O
885853
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00628
PipeID
P12529
Time
3:06 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8784
Sewer Name
15 SANTA ANITA CONNECTION TRUNK
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
WO_885853_TV15086_APR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0597
Downstream MH
15 0596
Dir. of Survey
Downstream
Length Surveyed
455.1 ft.
Total Length
455.1 ft.
Structural Index
2
Structural Quick
2300
Structural Rating
6
O&M Index
2
O&M Quick
2Q00
O&M Rating
180
Overall Index
2
Overall Quick
Overall Rating
186
Pipe schematic from manhole 15 0597 to 15 0596
MH: 15 0597MH: 15 0596downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 05970 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start36.7 ft. CS - Crack Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES105.5 ft. CS - Crack Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES208.8 ft. CS - Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES453.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish455.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE455.1 ft. AMH - Downstream Manhole, Survey Ends - 15 0596

Observation photos (6)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES

    36.7 ft. - Crack Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES

    105.5 ft. - Crack Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES

    208.8 ft. - Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    455.1 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (11)

DistanceCodeObservation
0MWM
455.1MGOCOCKROACHES IN MANHOLE
0AMH15 0597
208.8CS
36.7CS
0MWL
105.5CS
453.4DAGS
2DAGS
455.1AMH15 0596
0MGOCOCKROACHES IN MANHOLE

Properties (7)

additional_info
630069042021202
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2021-04-21T03:06:14-07:00
documentation
PRO PIPE
is_lateral_inspection
false