- Date
- 04/21/2021
- W/O
- 885853
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00628
- PipeID
- P12524
- Time
- 11:25 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8785
- Sewer Name
- 15 SANTA ANITA CONNECTION TRUNK
- City
- TEMPLE CITY
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- WO_885853_TV15086_APR2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 15 0592
- Downstream MH
- 15 0591
- Dir. of Survey
- Downstream
- Length Surveyed
- 287.7 ft.
- Total Length
- 287.7 ft.
- Structural Index
- 3
- Structural Quick
- 3221
- Structural Rating
- 8
- O&M Index
- 2
- O&M Quick
- 2J00
- O&M Rating
- 114
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 122
Pipe schematic from manhole 15 0592 to 15 0591 Observation photos (6)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

180.4 ft. - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

235.3 ft. - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

251.3 ft. - Crack Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

287.7 ft. - General Observation - COCKROACHES IN MANHOLE