Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 15, 2021, 09:22 AM
  • C 0374_C 0373_04152021_023535.mp4

Date
04/15/2021
W/O
886146
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00141
PipeID
P09837
Time
2:22 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8729
Sewer Name
C JOINT OUTFALL C - UNIT 8C
City
LAKEWOOD
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
06
Purpose
Routine Assessment
Project
RFIR_WO_886146_TV19080_APR2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
78 in.
Upstream MH
C 0374
Downstream MH
C 0373
Dir. of Survey
Downstream
Length Surveyed
531.1 ft.
Total Length
531.1 ft.
Structural Index
3
Structural Quick
3T00
Structural Rating
318
O&M Index
4
O&M Quick
4131
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
325
Pipe schematic from manhole C 0374 to C 0373
MH: C 0374MH: C 0373downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 03740 ft. MWL - Water Level, 15 %of cross sectional area2.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.2 ft. MGO - General Observation - MAG COAT35.1 ft. ID - Infiltration Dripper, at 02 o'clock, within 8 inches of joint: YES490.7 ft. IR - Infiltration Runner, from 08 to 04 o'clock, within 8 inches of joint: YES531.1 ft. AMH - Downstream Manhole, Survey Ends - C 0373531.1 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK531.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Infiltration Dripper, at 02 o'clock, within 8 inches of joint: YES

    35.1 ft. - Infiltration Dripper, at 02 o'clock, within 8 inches of joint: YES

  • Infiltration Runner, from 08 to 04 o'clock, within 8 inches of joint: YES

    490.7 ft. - Infiltration Runner, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
531.1AMHC 0373
531.1MGOCONNECTION AT THE MH 9 OC'LOCK
2.2SAP
0MWM
0AMHC 0374
531.1SAP
35.1ID
2.2MGOMAG COAT
0MWL
490.7IR

Properties (8)

additional_info
630074041421202
custom_field_three
AGGREGATE PROJECTING/INFILTRATION
custom_field_two
3
customer
1
datetime
2021-04-15T02:22:13-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
26760